Improve patient safety with xchange™.
Designed for patients during moderate to deep sedation and selected TIVA cases. Avoid complications from oxygen desaturations and hypercapnia while eliminating the need for invasive mechanical oral airways.

*National Sleep Foundation
*Centers for Disease Control & Prevention
*World Health Organization
The era of defaulting to invasive airways is over.
Noninvasive first. Every time it’s appropriate.
For too long, a mechanical airway — oral airway, supraglottic airway or intubation — was treated as necessary in most cases. Pneuma is changing that. Start with xchange™ noninvasive nasal CPAP: up to 20 cmH2O with EtCO2 monitoring. Escalate only if you must.
See how xchange™ worksPneuma’s philosophy of care. Clinical decisions rest with the provider; see the IFU for indications and warnings.
Airway obstruction is common — and serious.
Patients with medical issues that directly affect their breathing during procedures are on the rise.
Airway obstruction leading to oxygen desaturation and/or hypercapnia is a common and serious complication during moderate to deep sedation. This risk is particularly pronounced in patients with known airway pathology.
Which patients benefit? →A truly noninvasive perioperative airway management solution.
Engineered to perfect positive pressure to deliver high inspired oxygen (FiO₂) continuously throughout the procedure and extend its use into the recovery period if clinically indicated.

Adjustable Positive Airway Pressure
Delivers pressures up to 20 cmH₂O through an integrated adjustable pressure-limiting (APL) valve.
Real-Time Pressure Visualization
An integrated manometer allows clinicians to monitor delivered airway pressure.
Single-Use, Universal Design
A streamlined, disposable solution designed to simplify inventory management and clinical workflow.
Three steps. Standard equipment.
Mount
Mount nasal dock and adjust comfort straps.
Connect O₂
Connect O₂ line to wall oxygen.
Connect EtCO₂
Connect EtCO₂ line to monitor.
Then adjust and confirm pressures with the integrated APL valve and manometer.

More consistent EtCO₂ sampling.
Greater consistency in trace display due to ability to maintain seal, and higher accuracy and reliability of readings throughout procedure.
View clinical support- Greater consistency in trace display due to ability to maintain seal
- Higher accuracy and reliability of readings throughout procedure
- Proprietary air chamber directs flow to minimize EtCO₂ dilution and loss of visual monitoring curve
“For upper extremity procedures under sedation or TIVA, the xchange™ nasal dock has been a significant efficiency booster. It keeps the surgical field clear for precise work on the hand/wrist while providing reliable airway support.”Dr. Amar Patel — Orthopedic Surgeon, Hand and Upper Extremity
Training and clinical support for every xchange™ team.
xchange™ Academy is a value-add program for facilities evaluating xchange™ and for new customers — combining hands-on product training, live support, and direct access to our clinical experts.
Explore xchange™ AcademyMeet us at upcoming meetings.
ANESTHESIOLOGY 2026 — ASA Annual Meeting
American Society of Anesthesiologists · San Diego Convention Center, San Diego, CA · Exhibits Oct 17–19 · Event website
Missouri Association of Nurse Anesthetists (MOANA) Fall Meeting
Barnes-Jewish College – Goldfarb School of Nursing, St. Louis, MO · Exhibit hours Oct 24 · Event details
PGA80 — PostGraduate Assembly in Anesthesiology
New York State Society of Anesthesiologists · New York Marriott Marquis, New York, NY · Exhibits Dec 12–13 · Event website

Pneuma Therapeutics Partners With MED Alliance to Expand Distribution of xchange™ Anesthesia Airway Management Device
Read moreSee the xchange™ for yourself.
Call for samples and evaluation: 1-844-836-8458
customersupport@pneumatx.com
Order code: PX-XCS-20
